Fluke 500 Series Battery Analyzer
Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.
Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.
Voltage and Resistance Thresholds
Fluke Battery Analyzers allow you to quickly and easily define upper and lower measurement thresholds or tolerance ranges. During the testing process, measured values are automatically compared to the predefined threshold levels producing a PASS, FAIL or WARN indication after each measurement. A maximum of 10 sets of thresholds can be stored and threshold indications are determined based on the following criterion:
Fluke Battery Management Software
Fluke Battery Management Software Easily allows you to quickly and easily import data from the battery analyzer to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used compare results, switch results between conductance and resistance readings and perform trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports.
Fluke Battery Analyze mobile app
The BT521 offers wireless communication for data download and remote display while measuring via the dedicated Fluke Battery Analyzer mobile app (note: the Fluke BT521 is not currently Fluke Connect compatible). Using the Fluke Battery Analyze mobile app you can:
Fluke BT510 key features:
Fluke BT520 Key features: (Designed for measuring batteries in cabinets and hard to reach places)
All of the above plus
Fluke BT521 Key features: (Designed for users who need to incorporate temperature measuring)
* BTL20 not included with the Fluke BT-521
* Not currently compatible with Fluke Connect® app
The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
Range | Resolution | Accuracy | BT510 | BT520 | BT520ANG | BT521 | BT521ANG | |
Battery Resistance / Strap Resistance1 | 3 m? | 0.001 m? | 1% + 8 | ? | ? | ? | ||
1% +68 | ? | ? | ||||||
30 m? | 0.01 m? | 0.8% + 6 | ? | ? | ? | |||
0.8%+12 | ? | ? | ||||||
300 m? | 0.1 m? | 0.8% + 6 | ? | ? | ? | ? | ? | |
3000 m? | 1 m? | 0.8% + 6 | ? | ? | ? | ? | ? | |
VDC | 6 V | 0.001 V | 0.09% + 5 | ? | ? | ? | ? | ? |
60 V | 0.01 V | 0.09% + 5 | ? | ? | ? | ? | ? | |
600 V | 0.1 V | 0.09% + 5 | ? | ? | ? | ? | ? | |
1000 V | 1 V | 0.09% + 5 | ? | ? | ||||
VAC (45 Hz to 500 Hz with 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | ? | ? | ? | ? | ? |
Frequency (displayed with VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | ? | ? | ? | ? | ? |
AC voltage ripple (20 KHz Max) | 600 mV | 0.1 mV | 3% + 20 | ? | ? | ? | ? | ? |
6000 mV | 1 mV | 3% + 10 | ? | ? | ? | ? | ? | |
ADC/AAC (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | ? | ? | |||
Temperature | 0�C to 60�C | 1�C | 2�C (4�F) | ? | ? | |||
Meter mode | 999 records for each measurement position with time stamp | |||||||
Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp | |||||||
1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz. 2. Trigger level VAC: 10 mV, AAC: 10 A |
||||||||
Measurement Modes | BT510 | BT520 | BT521 | |||||
Resistance (m?) | ? | ? | ? | |||||
Battery voltage | ? | ? | ? | |||||
Voltage DC | ? | ? | ? | |||||
Voltage AC and frequency (Hz) | ? | ? | ? | |||||
Ripple volt | ? | ? | ? | |||||
Temperature of negative battery post (using BTL21 straight probes) | ? | |||||||
DC and AC current (and frequency) | ? | |||||||
DMM mode | ? | ? | ? | |||||
Sequence mode | ? | ? | ? | |||||
Discharge measurement mode | ? | ? | ? | |||||
Automatic measurement save | ? | ? | ? | |||||
Wireless communication | ? | |||||||
Memory view | ? | ? | ? | |||||
General Specifications - Battery Analyzer | ||||||||
Size (H x W x D) | 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) | |||||||
Weight | 850 g (1.9 lb) | |||||||
Screen dimensions | 7.7 x 5.6 cm (3 x 2.2 in) | |||||||
Interface | USB mini | |||||||
Warranty | 3 years | |||||||
General Specifications - BTL20ANG Angled Measurement Probe | ||||||||
Long angled probe (overall length) | 242.2 cm (95.38 in) | |||||||
Short angled probe (overall length) | 216.8 cm (85.38 in) | |||||||
Overall span (coil relaxed) | 10.1 cm (4 in) | |||||||
Overall maximum span (coil extended) | 109.2 cm (43 in) | |||||||
BTL20ANG probe tip angle | 20 degrees from horizontal | |||||||
Environment Specifications | ||||||||
Operating temperature | 0�C to 40�C | |||||||
Storage temperature | -20�C to 50�C | |||||||
Lithium-ion battery charging temperature | 0�C to 40�C | |||||||
Operating humidity | Non-condensing (10�C) | |||||||
? 80% RH (at 10�C to 30�C) | ||||||||
? 75% RH (at 30�C to 40�C) | ||||||||
Operating altitude | Sea level to 2000 meters | |||||||
Storage altitude | Sea level to 12,000 meters | |||||||
IP rating | IP40 | |||||||
Radio | FCC Class A | |||||||
Vibration requirements | MIL-PRF-28800F: Class 2 | |||||||
Drop test requirements | 1 meter | |||||||
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28�C or below 18�C | |||||||
Safety compliance | 600 V CAT III | |||||||
EMC | IEC 61326 | |||||||
ROHS | China, Europe | |||||||
Protection class 2 | Pollution Degree II | |||||||
Battery compliance | UN38.3 | |||||||
UL2054 | ||||||||
IEC62133 | ||||||||
2 G per IEC68-2-26, 25 G, and 29 |