TS 19 Test Sets

TS19 telephone test equipment features DataSafe™, Tone or Pulse operation, Talk/Monitor capabilities and last number redial.

  • High impedance DataSafeTM operation in monitor mode
  • Tone (DTMF) and pulse operation
  • Last number redial
  • Polarity indication in talk mode

The Fluke Networks TS19 Test Set combines all the essential test set features at an affordable price. This test set was specifically designed for in-house telecom technicians. Its high impedance monitor prevents accidental disruption of service from clipping onto a data line while in monitor mode, thus ensuring the integrity of critical data lines. Features such as tone (DTMF) or pulse operation, talk/monitor capabilities, polarity test button and last number redial make this test set the perfect combination of features and price.

Models & Accessories

Models

  • 19800003 TS19 test set with banana jacks to alligator clips
  • 19800009 TS19 test set with ABN

Specifications

Electrical

  • Loop Limit 2.4 kΩmaximum at 48 VDC (nominal 15 mA minimum loopcurrent)
  • DC Resistance (Talk Mode) 150 Ωtypical at 80 mA current
  • AC Impedance (Monitor Mode) Low impedance (Ring position) 600 Ωat 1 KHz typical
    High impedance (HI Z position) 100 kΩminimum at 1 KHz
  • Rotary Dial Output 10 pps .5 pps
  • Pulsing Rate 60 % ± 2 %
  • Percent Break 800 ms typical
  • Interdigit Interval Leakage During Break > 50 kΩ
  • DTMF Output ±1 % maximum
  • Tone Frequency Error Level per Tone Pair dBm maximum, – dBm minimum
  • High versus Low Tone Difference 4 dB maximum

Physical

  • Length 8.75 in (22.2 cm)Width
  • Width 2.375 in (6.03 cm)
  • Height 3.375 in (8.57 cm)
  • Weight 10.8 oz (.307 kg) maximum

Environmental

  • Temperature  Operating: -5 °C to °C Storage: -40 °C to °C
  • Drop 1 meter, 4 times
  • Altitude To 3,000 meters (10,000 feet) maximum
  • Relative Humidity 10 %to 80 % (non-condensing)
  • Regulatory Standards Used 47 CFR Part 15, Subpart B
    ICES-003 Issue 3
    AS/NZS 3548
    EMC Directive 89/336/EEC, EN 55022:98, EN 61326:97, A1:98 Annex C, EN 61000-4-2, EN 61000-4-3
    LV Directive 73/23/EEC, EN 610010.1 (1993)
  • Certifications and Compliance CAN/CSA-C22.2 No. 60950-1-03
    CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1

Looking for the Best Engineering Solution for your Project?

WhatsApp Chat with us