Number of Channels
(all channels are acquired including clocks) - TLA7AA1:
34 channels (2 are clock channels).
TLA7AA2, TLA7AB2: 68 channels (4 are clock channels).
TLA7AA3: 102 channels (4 are clock and 2 are qualifier
channels).
TLA7AA4, TLA7AB4: 136 channels (4 are clock and 4
are qualifier channels).
Channel Grouping: No limit to number of groups or
number of channels per group (all channels can be
reused in multiple groups).
Module "Merging" - Up to five 102 channel
or 136 channel modules can be "merged" to make up
to a 680 channel module. Merged modules exhibit
the same depth as the lesser of the five individual
modules.
Word/setup-and-hold/glitch/transition recognizers
span all five modules. Range recognizers limited to
three module merge. Only one set of clock connections
is required.
Time Stamp - 51-Bits at 125 ps resolution
(3.25 days duration).
Clocking/Acquisition Modes - Internal, internal
2X, internal 4X, external, external 2X, external 4X,
source synchronous. 8 GHZ MagniVu high-speed
timing is available simultaneous with all modes.
Number of Mainframe Slots Required per TLA Series
Module - 2.
Input Characteristics (with P68xx or P69xx probes)
Capacitive Loading -
0.5 pF clock/data (P69xx)
<0.7 pF clock/data (P68xx)
(1.0 pF for P6810 in group configuration).
Threshold Selection Range - From -2.0 V
to +4.5 V in 5 mV increments.
Threshold presets include TTL (1.5 V), CMOS
(1.65 V), ECL (-1.3 V), PECL (3.7 V),
LVPECL (2.0 V), LVCMOS 1.5 V (0.75 V),
LVCMOS 1.8 V (0.9 V), LVCMOS 2.5 V
(1.25 V), LVCMOS 3.3 V (1.65 V), LVDS
(0 V) and user-defined.
Threshold Selection Channel Granularity - Separate
selection for each of the clock/qualifier channels
and one per group of 16 data channels for each 34
channel probe.
Threshold Accuracy (including probe) - ±(35 mV
+ 1%).
Input Voltage Range - Operating: -2.5 V
to 5.0 V.
Nondestructive: ±15 V.
Minimum Input Signal Swing - 300 mV (single-ended).
V¯MAX - VMIN > 150 mV
(differential).
Input Signal Minimum Slew Rate - 200 mV/ns
typical.
State Acquisition Characteristics (with
P68xx or P69xx probes)
State Acquisition
|
Full Channel |
Half Channel |
Quarter Channel |
|
120 MHZ Standard |
235 MHZ/235 Mb/s or 240 Mb/s
(DDR) |
235 MHZ/470 Mb/s |
|
235 MHZ Optional |
450 MHZ/450 Mb/s or 470 Mb/s
(DDR) |
450 MHZ/900 Mb/s |
|
450 MHZ Optional |
800 MHZ/800 Mb/s or 900 Mb/s
(DDR) |
625 MHZ/1.25 Gb/s |
State Memory Depth with Timestamps - (quarter/half/full
channels) 512/256/128 KB, 2 Mb/1 Mb/512 KB,
8/4/2 Mb, 32/16/8 Mb, 128/64/32 Mb,
256/128/64 Mb per channel.
Setup and Hold Time Selection Range - From
16 ns before, to 8 ns after clock edge in
125 ps increments. Range may be shifted towards
the setup region by 0 ns [+8, -8] ns, 4 ns
[+12, -4] ns, or 8 ns [+16, 0] ns.
Setup-and-hold Window - All Channels: 625 ps
typical.
Single Channel: 500 ps typical.
Minimum Clock Pulse Width - 500 ps (P6960,
P6964, P6980, P6982, P6860, P6864, P6880), 700 ps
(P6810).
Active Clock Edge Separation - 400 ps.
Demux Channel Selection - Channels can be
demultiplexed to other channels through user interface
with 8 channel granularity.
Source Synchronous Clocking - Up to four "Fast
Latches" per module (20 max per 5-way merge)
to strobe source-synchronous buses into TLA7Axx Modules.
Four sets of any predefined "Fast Latches" may be
combined with qualification data and data pipelining
to store four independent source-synchronous data
buses.
Two "Fast Latches" may be combined to address DDR
applications.
Timing Acquisition Characteristics (with P68xx or
P69xx probes)
MagniVuT Timing - 125 ps max, adjustments
to 250 ps, 500 ps, 1 ns, and 2 ns.
MagniVu Timing Memory Depth - 16 KB per
channel, with adjustable trigger position.
Deep Timing Resolution (quarter/half/full channels)
- 500 ps/1 ns/2 ns to 50 ms.
Deep Timing Resolution with Glitch Storage Enabled
- 4 ns to 50 ms.
Deep Timing Memory Depth (quarter/half/full channels
with timestamps and with or without transitional storage)
- 512/256/128 KB, 2 Mb/1 Mb/512 KB,
8/4/2 Mb, 32/16/8 Mb,128/64/32 Mb,
256/128/64 Mb per channel.
Deep Timing Memory Depth with Glitch Storage Enabled
- Half of default main memory depth.
Channel-to-channel Skew - 300 ps typical.
Minimum Recognizable Pulse/Glitch Width (single
channel) - 500 ps (P6960, P6964, P6980, P6982,
P6860, P6864, P6880), 750 ps (P6810).
Minimum Detectable Setup/Hold Violation - 250 ps.
Minimum Recognizable Multi-channel Trigger Event
- Sample period + channel-to-channel skew.
Analog Acquisition Characteristics (with P68xx or
P69xx probes)
Bandwidth - 2 GHZ typical.
Attenuation - 10x, ±1%.
Offset and Gain (Accuracy) - ±50 mV,
+/-2% of Signal Amplitude.
Channels Demultiplexed - 4.
Run/Stop Requirements - None, analog outputs
are always active.
iViewT Analog Outputs - Compatible with any
internal TLA7Dx/Ex DSO module or supported TDS external
oscilloscope.
iView Analog Output BNC Cable - Low loss,
10x, 36-in.
Trigger Characteristics
Independent Trigger States - 16.
Maximum Independent If/then Clauses per State
- 16.
Maximum Number of Events per If/then Clause -
8.
Maximum Number of Actions per If/then Clause -
8.
Maximum Number of Trigger Events - 18 (2 counter/timers
plus any 16 other resources).
Number of Word Recognizers - 16.
Number of Transition Recognizers - 16.
Number of Range Recognizers - 4.
Number of Counter/Timers - 2.
Trigger Event Types - Word, group, channel,
transition, range, anything, counter value, timer
value, signal, glitch, setup-and-hold violation, snapshot.
Trigger Action Types - Trigger module, trigger
all modules, trigger main, trigger MagniVu, store,
don't store, start store, stop store, increment counter,
decrement counter, reset counter, start timer, stop
timer, reset timer, snapshot current sample, goto
state, set/clear signal, do nothing.
Maximum Triggerable Data Rate - 1250 Mb/s
(4X clocking mode).
Trigger Sequence Rate - DC to 500 MHZ
(2 ns).
Counter/Timer Range - 51 Bits each (>50
days at 2 ns).
Counter Rate - DC to 500 MHZ (2 ns).
Timer Clock Rate - 500 MHZ (2 ns).
Counter/Timer Latency - 2 ns.
Range Recognizers - Double bounded (can be
as wide as any group (408 channel max), must be grouped
according to specified order of significance).
Setup-and-hold Violation Recognizer Setup Time
Range - From 8 ns before to 7 ns after
clock edge in 125 ps increments. This range may
be shifted towards the positive region by 0 ns,
4 ns, or 8 ns.
Setup-and-hold Violation Recognizer Hold Time
Range - From 7 ns before to 8 ns after
clock edge in 125 ps increments. This range may
be shifted towards the positive region by 0 ns
[+8, -8] ns, 4 ns [+12, -4] ns, or 8 ns
[+16, 0] ns.
Trigger Position - Any data sample.
MagniVu Trigger Position - MagniVu position
can be set from 0% to 60% centered around the MagniVu
trigger.
Storage Control (data qualification) - Global
(conditional), by state (start/stop), block, by trigger
action, or transitional. Also force main prefill selection
available.
Physical Characteristics
|
Dimensions |
mm |
in. |
|
Height |
262 |
10.3 |
|
Width |
61 |
2.4 |
|
Depth |
381 |
15 |
|
Weight |
kg |
lb. |
|
Net |
3.1 |
6.7 |
|
Shipping |
6.3 |
13.7 |
|