TDS8200 Digital Sampling Oscilloscope

Features:
  • DC to 70+ GHZ*1 Bandwidth
  • Industry-leading Timebase Accuracy
    • Jitter <200 fsRMS with 82A04
    • 800 fsRMS Standard
  • Modular Architecture with Up to Eight Acquisition Channels
  • Advanced Jitter, Noise, and BER analysis
    • Analysis of High-speed Serial Data Rates from 1 Gb/s to 60 Gb/s Provides Insight into Precise Causes of Eye Closure
    • Separation of Both Jitter and Noise Provides Highly Accurate Extrapolation of BER and Eye Contour
  • High performance TDR/TDT
    • True Differential Step Generator and Signal Acquisition
    • <28 ps Reflected Rise Time
    • Up to 4 Differential Pairs (8 channels)
    • High Fidelity Differential and Single-ended Probing
  • Automated Standards Mask Testing
    • Communications Standards including Sonet/SDH, Ethernet, OIF, and Fibre Channel
    • Computer Standards including SATA, SAS, PCI Express, and Rapid IO
  • Automated Measurement System with Over 100 NRZ, Pulse, and RZ Measurements
  • FrameScan® Acquisition Mode
    • Isolate Data Dependent Faults
    • Signal Averaging to Examine Low-power Signal
  • Four Color Graded Variable Persistence Waveform Databases
  • Microsoft Windows 2000 Operating System
Digital Oscilloscopes
TDS8200

Applications

  • Signal Integrity, Advanced Jitter, Noise, and BER Analysis
  • Characterization of Next-generation Digital Designs
  • Design Characterization and Manufacturing Compliance Test of Telecom, Datacom, Storage Area Network, Computer, and High-speed Backplane Designs
  • TDR, Impedance Characterization, and Cross Talk Measurements for PCBs, Cables, and IC Packages

*1 Bandwidth is determined by plug-in modules and may exceed 70 GHZ as higher speed modules become available in the future.

Characteristics/Specs
Signal Acquisition

Acquisition Modes - Sample (normal), Envelope, and Average.

Number of Sampling Modules Accommodated -

Up to four dual-channel electrical; up to two optical sampling modules. (Both single- and dual-channel modules appropriate the two channels associated with the slot).

Population of the Ch 1/Ch 2 large slot with any module other than the one requiring power only displaces functionality of the Ch 1/Ch 2 small slot; population of the Ch 3/Ch 4 large slot with any module other than one requiring power only displaces functionality of the Ch 3/Ch 4 small slot.

 

Number of Simultaneously Acquired Inputs - Eight channels maximum.

Vertical Systems

Rise Time/Bandwidth - Determined by the sampling modules used.

Vertical Resolution - 14 bits over the sampling modules' dynamic range.

Horizontal System

Four timebase modes are available:

Triggered Phase Reference*1 timebase mode - timing information extracted from a user supplied phase reference (clock) signal significantly improves timebase accuracy and jitter performance of the triggered acquisition.  Horizontal position is referenced to the trigger signal as with a traditional timebase.

Free Run Phase Reference*1 timebase mode - all timing is based on a phase reference signal; accuracy and jitter as above; no trigger is needed, and correspondingly there is no timing relation to trigger signal.

Short Term Optimized Sequential*2 timebase mode - best short-delay performance for acquisitions without the external phase reference signal.

Locked to 10 MHZ Reference Sequential timebase - provides the best long-delay performance for acquisitions without the external phase reference signal.  The Lock is selectable between Lock to Internal 10 MHZ and Lock to External 10 MHZ for highest frequency accuracy.

Main and Magnification View Timebases - 100 fs/div to 5 ms/div in 1-2-5 sequence, or 100 fs increments.

Maximum Trigger Rate - 200 KHZ; in Phase Reference mode: 50KHZ.

Typical Acquisition Rate - 150 KS/s per channel (standard sequential timebase); 50 KS/s (Phase Reference modes).

Time Interval Accuracy (Standard Timebase) and Timing Deviation (Phase Reference modes)

Phase Reference timebase -

Triggered: maximum timing deviation relative to phase reference signal:

horizontal position >40 ns after trigger event:

 0.2% of phase reference signal period (typical)

horizontal position ≤ 40 ns after trigger event:

0.4% of phase reference signal period (typical)

 

Phase Reference timebase -

Free Run: maximum timing deviation relative to phase reference signal:

0.1% or better of phase reference signal period (typical)

 

Sequential timebase*2 -

Time Interval Accuracy:

Horizontal scale: <21 ps/div:

1 ps + 1% of interval.

Horizontal scale: ≥21 ps/div:

8 ps + 0.1% of interval (Short-term optimized mode).

8 ps + 0.01% of interval (Locked to 10 MHZ mode).

 

Horizontal Deskew Range available (Sequential timebase only) - -500 ps to +100 ns on any individual channel in 100 fs increments.

Record Length - 20, 50, 100, 250, 500, 1000, 2000, or 4000 samples.

Magnification Views - In addition to the main timebase, the CSA/TDS8200 supports two magnification views. These magnifications are independently acquired using separate timebase settings which allow same or faster time/div than that of the main timebase.

*1 When using the 82A04 Phase Reference Module.

*2 Conventional mode - not using the 82A04 Phase Reference Timebase Module.

Trigger System

Trigger Sources

External direct trigger

External pre-scaled trigger

Internal clock trigger: Internally connected to direct trigger

Clock recovery triggers from optical sampling modules, and from the 80A05 electrical clock recovery module -signal from the module (pre-scaled above 2.7 Gb/s) internally connected.

Phase Reference*3 timebase supports acquisitions without a trigger signal in its Free Run mode.

Trigger Sensitivity

External direct trigger output -

50 mV, DC - 4 GHZ (typical).

100 mV, DC - 3 GHZ (guaranteed).

 

Pre-scaled trigger input - 200 mVPk-Pk to 800 mVPk-Pk, 2 to 12.5 GHZ (guaranteed)

Jitter

Phase Reference*3 timebase -

System jitter of 200 fsRMS typical on a 10 GHZ or faster acquisition module, with f ≥ 8 GHZ, 0.6V ≤ VREF ≤ 1.8 V Phase Reference Signal.

Jitter: system jitter of 280 fsRMS typical on a 10 GHZ or faster acquisition module, in CSA/TDS8200 mainframe, with 2 GHZ ≤ f ≤ 8 GHZ, 0.6V ≤ VREF ≤ 1.8 V Phase Reference Signal.

The Phase Reference timebase remains operational to 100 mV (typical) with increased jitter.

 

Short-term jitter optimized Sequential mode: -

≤0.8 ps RMS +5 ppm of position (typical).

≤1.2 ps RMS +10 ppm of position (max.).

 

Locked to 10 MHZ reference Sequential mode: -

≤1.6 ps RMS +0.04 ppm of position (typical).

≤2.5 ps RMS +0.01 ppm of position (max.).

 

Internal Clock - Adjustable from 25 to 200 KHZ (drives TDR, internal clock output and calibrator).

Trigger Level Range - ±1.0 V.

Trigger Input Range - ±1.5 V.

Trigger Holdoff - Adjustable 5 µs to 100 ms in 0.5 ns increments.

External Trigger Gate (optional) - TTL logic 1 enables gate, a TTL logic 0 disables gate, maximum non-destruct input level ±5 V.

*3 When using the 82A04 Phase Reference Module.

Display Features

Touch Screen Display - 264 mm/10.4 in. diagonal, color.

Colors - 16,777,216 (24 bits).

Video Resolution - 640 horizontal by 480 vertical displayed pixels.

Monitor Type - LCD monitor

Math/Measurement

System Measurements

The CSA/TDS8200 supports up to eight simultaneous measurements, updated three times per second with optional display of per measurement statistics (min, max, mean, and standard deviation).

Measurement Set

Automated Measurements include RZ, NRZ, and Pulse signal types, and the following:

Amplitude Measurements - High, Low, Amplitude, Max, Mid, Min, +Width, Eye Height, Eye Opening Factor, Pulse Symmetry, Peak-to-Peak, OMA, +Overshoot, -Overshoot, Mean, +Duty Cycle, Cycle Mean, RMS, Cycle RMS, AC RMS, Gain, Extinction Ratio (Ratio, %, dB), Suppression Ratio (Ratio, %, dB),  Peak-to-Peak Noise, RMS Noise, Q-Factor, SNR, Average Optical Power (dBm, watts), OMA.

Timing Measurements - Rise, Fall, Period, Bit Rate, Bit Time, Frequency, Crossing (%, Level, Time), +Cross, -Cross, Jitter (Pk-Pk, RMS), Eye Width, +Width, -Width, Burst Width, +Duty Cycle, -Duty Cycle, Duty Cycle Distortion, Delay, Phase.

Area Measurements - Area, Cycle Area.

Cursors

Dot, vertical bar, and horizontal bar cursors.

Waveform Processing

Up to eight math waveforms can be defined and displayed using the following math functions: Add, Subtract, Multiply, Divide, Average, Differentiate, Exponentiate, Integrate, Natural Log, Log, Magnitude, Min, Max, Square Root, and Filter.

In addition, measurement values can be utilized as scalars in math waveform definitions.

Mask Testing

In addition to user-defined masks, the following predefined masks are built-in:

Standard Rate (Gb/s) unless otherwise noted -

STM-0/oc-1 51.8 Mb/s

STM-1/oc-3 155 Mb/s

STM-4/oc-12 622 Mb/s

STM-16/oc-48 2.488

STM-64/oc-192 9.953

STM-256/oc-768 39.813

FEC 2.666 2.666

FEC 10.66 10.664

FEC 10.709 10.709

FEC 43 Gb/s G.709 43.018

FEC 42.66 42.657

FC-10 G 10.51875

FC-133 132.8 Mb/s

FC-266 265.6 Mb/s

FC-531 531.2 Mb/s

FC-1063 1.063

FC-2125 2.125

FC-4250 4.250

10 G BASE-X4 3.125

10 G BASE-W 9.953

10 G BASE-R 10.3125

InfiniBand 2.500

Gigabit Ethernet 1.2500

XAUI 3.125

 

 

Optical Sampling Module Characteristics

Optical Sampling Module Characteristics (Refer to Optical Sampling Modules User Manual for more detailed information)

 

    Application Type Standards and Supported Filtering Rates Number of Input Channels Effective Wavelength Range Calibrated Wavelengths
80C02 10 Gb/s Telecom oc-192/STM-64 (9.953 Gb/s)

10GBASE-W (9.953 Gb/s)

1 1100 nm to 1650 nm 1310 nm and 1550 nm (±20 nm)
80C07B Tributary Datacom/Telecom Standard Included:oc-48/STM-16 (2.488 Gb/s), Infiniband, 2 GbE (2.500 Gb/s); Optional (choose any two):oc-3/STM-1 (155 Mb/s),oc-12/STM-4 (622 Mb/s), FibreChannel (1.063 Gb/s), GbE (1.250 Gb/s), 2G FibreChannel (2.125 Gb/s) 1 700 nm to 1650 nm 780 nm, 850 nm, 1310 nm, and 1550 nm (±20 nm)
80C08C 10 Gb/s Datacom/Telecom oc-192/STM-64 (9.953 Gb/s), 10GBASE-W (9.953 Gb/s), 10GBASE-R (10.310 Gb/s), 10G Fibre Channel (10.520 Gb/s), ITU-T G.975 FEC (10.664 Gb/s), ITU-T G.709 (10.709 Gb/s),10 GbE FEC (11.100 Gb/s) 1 700 nm to 1650 nm 780 nm, 850 nm, 1310 nm, and 1550 nm (±20 nm)
80C10 40 Gb/s Telecom oc-768/STM-256 (39.813 Gb/s), ITU-T G.709 FEC (43.018 Gb/s) 1 1310 nm and 1550 nm 1310 nm and 1550 nm (±20 nm)
80C11 10 Gb/s Datacom/Telecom oc-192/STM-64 (9.953 Gb/s), 10GBASE-W (9.953 Gb/s), 10GBASE-R (10.310 Gb/s), 10G Fibre Channel (10.520 Gb/s), ITU-T G.975 FEC (10.664 Gb/s), ITU-T G.709 (10.709 Gb/s), 10 GbE FEC (11.100 Gb/s) 1 1100 nm and 1650 nm 1310 nm and 1550 nm (±20 nm)
80C12 1 to 4.5 Gb/s Datacom/Telecom FibreChannel (1.063 Gb/s), 2G FibreChannel (2.125 Gb/s), 4G FibreChannel (4.250 Gb/s) 10GBase-X4 (3.125 Gb/s) 10GFC-X4 (3.1875 Gb/s) VSR5-3318 (3.318 Gb/s) 1 700 nm to 1650 nm 850 nm, 1310 nm, and 1550 nm (±20 nm)
10 Gb/s Datacom/Telecom oc-192/STM-64 (9.953 Gb/s), 10GBASE-W (9.953 Gb/s), 10GBASE-R (10.310 Gb/s), 10G Fibre Channel (10.520 Gb/s), ITU-T G.975 FEC (10.664 Gb/s), ITU-T G.709 (10.709 Gb/s), 10 GbE FEC (11.100 Gb/s)

 

Optical Sampling Module Characteristics (continued)

 

    Clock Recovery (Optional) Clock Recovery Outputs Unfiltered Optical Bandwidth*4 Absolute Maximum Nondestructive Optical Input Internal Fiber Diameter
80C02 Option CR: 9.953 Gb/s Clock, Clock/16, Data 28 GHZ 5 mW average; 10 mW peak power at wavelength of highest relative responsivity 9  μm/125 μm single-mode
80C07B Option CR1: 155 Mb/s, 622 Mb/s, 1.063 Gb/s, 1.250 Gb/s, 2.125 Gb/s, 2.488 Gb/s, 2.500 Gb/s, 2.666 Gb/s ±Clock, ±Data 2.5 GHZ 5 mW average; 10 mW peak power at wavelength of highest responsivity 62.5 μm/125 μm multi-mode
80C08C Option CR1: 9.953 Gb/s, 10.310 Gb/s;

Option CR2: 10.310 Gb/s, 10.520 Gb/s;

Option CR4: Continuous from 9.800 Gb/s to 12.600 Gb/s

Clock, Clock/16 10 GHZ 1 mW average; 10 mW peak power at wavelength of highest responsivity 62.5 μm/125 μm multi-mode
80C10 Future Upgradeable Future 65 GHZ 20 mW average; 60 mW peak power at wavelength of highest relative responsivity 9 μm/125 μm single-mode
80C11 Option CR1: 9.953 Gb/s;

Option CR2: 9.953 Gb/s, 10.664 Gb/s;

Option CR3: 9.953 Gb/s, 10.709 Gb/s;

Option CR4: Continuous between 9.800 Gb/s to 12.600 Gb/s

CR1: Clock, Clock/16, Data;

CR2, CR3, CR4: Clock, Clock/16

28 GHZ 5 mW average; 10 mW peak power at wavelength of highest responsivity 9 μm/125 μm single-mode
80C12 Provided by 80A05 (sold separately) ELECTRICAL SIGNAL OUT 9 GHZ (for all options except 10G)

10 GHZ (option 10G)

1 mW average; 10 mW peak power at wavelength of highest responsivity 62.5 μm/125 μm multi-mode

 

*4 Values shown are warranted unless printed in an italic typeface which represents a typical value.

Optical Sampling Module Characteristics (continued)

    Optical Return Loss Fiber Input Accepted RMS Optical Noise (typical) RMS Optical Noise (maximum) Independent Channel Deskew
80C02 >30 dB single-mode 6.0 μW at 9.953 Gb/s, 12.5 GHZ;

10.0 μW at 20 GHZ;

15.0 μW at 30 GHZ

10.0 μW at 9.953 Gb/s, 12.5 GHZ mode;

15 μW at 20 GHZ;

30 μW at 30 GHZ

Standard
80C07B >14 dB (multi-mode) >24 dB (single-mode) single- or multi-mode 0.50 μW at 155 Mb/s, 622 Mb/s, 1063 Mb/s, 1250 Mb/s;

0.70 μW at 2.488/2.500 Gb/s

1.0 μW at 155 Mb/s, 622 Mb/s, 1063 Mb/s, 1250 Mb/s;

1.5 μW at 2.488/2.500 Gb/s

Standard
80C08C >14 dB (multi-mode) >24 dB (single-mode) single- or multi-mode 1.7 μW at all filter rates 3.0 μW at all filter rates Standard
80C10 >30 dB single-mode 40 μW at 39.813 Gb/s, 43.018 Gb/s (1550 nm); 75 μW at 39.813  Gb/s, 43.018 Gb/s (1310 nm);

30 μW at 30 GHZ mode (1550 nm); 55 μW at 30 GHZ mode (1310 nm);

85 μW at 65 GHZ mode (1550 nm); 150 μW at 65 GHZ mode (1310 nm)

60 μW at 39.813 Gb/s, 43.018 Gb/s (1550 nm); 110 μW at 39.813 Gb/s, 43.018 Gb/s (1310 nm);

50 μW at 30 GHZ (1550 nm); 90 μW at 30 GHZ (1310 nm);

120 μW at 65 GHZ (1550 nm); 220 μW at 65 GHZ (1310 nm)

Standard
80C11 >30 dB single-mode 5.5 μW at all filter rates;

10.0 μW at 20 GHZ

20.0 μW at 30 GHZ

8.0 μW at all filter rates;

14.0 μW at 20 GHZ

30.0 μW at 30 GHZ

Standard
80C12 >14 dB (multi-mode)

>24 dB (single-mode)

single- or multi-mode 1.7 μW (all filters except option 10G)

3.4 μW (Full BW and option 10G filters)

3.0 μW (all filters except option 10G)

6.0 μW (Full BW and option 10G filters)

Standard

 

Optical Sampling Module Characteristics (continued)

 

    Offset Capability Power Meter Power Meter Range Power Meter Accuracy Mask Test Optical Sensitivity*5
80C02 Standard Standard +4 dBm to -30 dBm 5% of reading -9 dBm at 9.953 Gb/s; -7 dBm at 20 GHZ; -4 dBm at 30 GHZ
80C07B Standard Standard +4 dBm to -30 dBm 5% of reading -22 dBm at 155 Mb/s, 622 Mb/s; -20 dBm at 2488/2500 Mb/s
80C08C Standard Standard 0 dBm to -30 dBm 5% of reading -16 dBm at all filter rates
80C10 Standard Standard +13 dBm to -21 dBm 5% of reading 0 dBm at 39.813 Gb/s, 43.018 Gb/s; 0 dBm at 30 GHZ; +3 dBm at 65 GHZ
80C11 Standard Standard +4 dBm to -30 dBm 5% of reading -10 dBm at all filter rates; -7 dBm at 20 GHZ; -4 dBm @ 30 GHZ
80C12 Standard Standard 0 dBm to -30 dBm 5% of reading

-15 dBm (for all options except option 10G)

-12 dBm (for option 10G)

 

*5 Smallest power level for mask test. Values represent theoretical typical sensitivity of NRZ eyes for competitive comparison purposes. Assumes instrument peak-peak noise consumes most of the mask margin.

Physical Characteristics for Optical Sampling Modules

 

    Dimensions (mm/inches) Weight (kg/lb)
    Width Height Depth Net
80C02 165/6.5 25/1.0 305/12.0 <2.61/<5.75
80C07B 165/6.5 25/1.0 305/12.0 <1.36/<3.0
80C08C 165/6.5 25/1.0 305/12.0 <1.22/<2.7
80C10 165/6.5 25/1.0 305/12.0 <2.61/<5.75
80C11 165/6.5 25/1.0 305/12.0 <1.22/<2.7
80C12 165/6.5 25/1.0 305/12.0 <2.61/<5.75

Electrical Sampling Module Characteristics

    Application Type Channels Input Impedance Channel Input Connector Bandwidth*6
80E01 Microwave General Purpose 1 50 ±0.5 Ω 2.4 mm female precision adapter to 2.92 mm included with 50 Ω SMA termination 50 GHZ
80E02 Low-level Signals 2 50 ±0.5 Ω 3.5 mm female 12.5 GHZ*7
80E03 Device Characterization 2 50 ±0.5 Ω 3.5 mm female 20 GHZ*7
80E04 TDR Impedance Characterization with single-ended, common, differential TDR capability 2 50 ±0.5 Ω 3.5 mm female 20 GHZ*7
80E06 High-speed Electrical Device Characterization 1 50 ±0.5 Ω 1.85 mm female precision adapter to 2.92 mm included with 50 Ω SMA termination 70+ GHZ

 

*6 Values shown are warranted unless printed in an italic typeface which represents a non-warranted characteristic value that the instrument will typically perform to.

*7 Calculated from 0.35 bandwidth rise time product.

Electrical Sampling Module Characteristics (continued)

    Rise Time (10% to 90%) Dynamic Range Offset Range Maximum Input Voltage Vertical Number of Digitized Bits
80E01 7 ps (typical)*7 1.0 Vp-p ±1.6 V ±2.0 V 14 bits full scale
80E02 ≤28 ps 1.0 Vp-p ±1.6 V ±3.0 V 14 bits full scale
80E03 ≤17.5 ps 1.0 Vp-p ±1.6 V ±3.0 V 14 bits full scale
80E04 ≤17.5 ps 1.0 Vp-p ±1.6 V ±3.0 V 14 bits full scale
80E06 5.0 ps*8 1.0 Vp-p ±1.6 V ±2.0 V 14 bits full scale

*7 Calculated from 0.35 bandwidth rise time product.

*8 80E06 rise time is calculated from formula rise time = 0.35/(typical bandwidth).

Electrical Sampling Module Characteristics (continued)

    Vertical Sensitivity Range DC Vertical Voltage Accuracy, single point, within ±2 °C of compensated temperature Typical Step Response Aberrations*9 RMS Noise*9
80E01 10 mV to 1.0 V full scale ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] ±3% or less over the zone 10 ns to 20 ps before step transition; +12%, -5% or less for the first 300 ps following step transition; +5.5%, -3% or less over the zone 300 ps to 3 ns following step transition; ±1% or less over the zone 3 ns to 100 ns following step transition; ±0.5% after 100 ns following step transition 1.8 mV≤2.3 mV (maximum)
80E02 10 mV to 1.0 V full scale ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] ±3% or less over the zone 10 ns to 20 ps before step transition; +10%, -5% or less for the first 300 ps following step transition; ±3% or less over the zone 300 ps to 5 ns following step transition; ±1% or less over the zone 5 ns to 100 ns following step transition; ±0.5% after 100 ns following step transition 400 μV≤800 μV (maximum)
80E03 10 mV to 1.0 V full scale ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] ±3% or less over the zone 10 ns to 20 ps before step transition; +10%, -5% or less for the first 300 ps following step transition; ±3% or less over the zone 300 ps to 5 ns following step transition; ±1% or less over the zone 5 ns to 100 ns following step transition; ±0.5% after 100 ns following step transition 600 μV≤1.2 mV (maximum)
80E04 10 mV to 1.0 V full scale ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] ±3% or less over the zone 10 ns to 20 ps before step transition; +10%, -5% or less for the first 300 ps following step transition; ±3% or less over the zone 300 ps to 5 ns following step transition; ±1% or less over the zone 5 ns to 100 ns following step transition; 0.5% after 100 ns following step transition 600 µV≤1.2 mV (maximum)
80E06 10 mV to 1.0 V full scale ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] ±5% or less for first 300 ps following step transition 1.8 mV ≤2.4 mV (maximum)

 

*9 Values shown are warranted unless printed in an italic typeface which represents a non-warranted characteristic value that the instrument will typically perform to.

Physical Characteristics for Electrical Sampling Modules

 

    Dimensions (mm/in.) Weight (kg/lbs.)
    Width Height Depth Net
80E01 79/3.1 25/1.0 135/5.3 0.4/0.87
80E02 79/3.1 25/1.0 135/5.3 0.4/0.87
80E03 79/3.1 25/1.0 135/5.3 0.4/0.87
80E04 79/3.1 25/1.0 135/5.3 0.4/0.87
80E06 79/3.1 25/1.0 135/5.3 0.4/0.87

 

Electrical TDR System (80E04 only) Characteristics

 

    80E04*9
Channels 2
Input Impedance 50 ±0.5 Ω
Channel Input Connector 3.5 mm
Bandwidth 20 GHZ
TDR Step Amplitude 250 mV (polarity of either step may be inverted)
TDR System Reflected Rise Time 28 ps (typical)
TDR System Incident Rise Time 17 ps (typical)
TDR Step Maximum Repetition Rate 200 KHZ
TDR System Step Response Aberrations ±3% or less over the zone 10 ns to 20 ps before step transition;
+10%, -5% or less typical for the first 400 ps following step transition;
±3% or less over the zone 400 ps to 5 ns following step transition;
±1% or less after 5 ns following step transition

 

*9 Values shown are warranted unless printed in an italic typeface which represents a non-warranted characteristic value that the instrument will typically perform to.

80A05 Electrical Clock Recovery Module

 

           
Enumerated Standards

(Basic equipment)

Standard

oc3/STM1

oc12/STM4

Fibre Channel

Gigabit Ethernet

Gigabit Fibre Channel

oc48/STM16

2 Gigabit Ethernet

Infiniband

2.5G G.709 FEC

4 Gigabit Fibre Channel

Rate

155.52 Mb/s

622.08 Mb/s

1.063 Gb/s

1.250 Gb/s

2.125 Gb/s

2.488 Gb/s

2.500 Gb/s

2.500 Gb/s

2.666 Gb/s

4.250 Gb/s

Clock Recovery Ranges

(Basic equipment, for user-specified rates)

Range

50 Mb/s to 2.700 Gb/s

3.00 Gb/s to 3.188 Gb/s

Emerging Standards

VSR5

PCI Express, SATA, SATA-2, XAUI, 4-Lane 10FC

Enumerated Standards

(Added with Option 10G)

Standard

oc192/STM64

10GBase-W

10GBase-R

10G Fibre Channel

G.975 FEC

G.709 FEC

10 GbE with FEC

Rate

9.953 Gb/s

9.953 Gb/s

10.31 Gb/s

10.51 Gb/s

10.66 Gb/s

10.71 Gb/s

11.10 Gb/s

Clock Recovery Ranges

(Added with Option 10G, for user-specified rates)

Range

2.7 Gb/s to 3.0 Gb/s

3.267 Gb/s to 4.250 Gb/s

4.900 Gb/s to 6.375 Gb/s

9.800 Gb/s to 12.60 Gb/s

Emerging Standards

SATA-3, 2x XAUI, PCI Express 2,oc192 Super FEC

Sensitivity

50 Mb/s to 2.70 Gb/s

2.70 Gb/s to 11.19 Gb/s

11.19 Gb/s to 12.60 Gb/s

Differential

≤8 mVp-p on each input

≤12 mVp-p on each input

≤15 mVp-p on each input

Single-Ended

10 mVp-p

15 mVp-p

20 mVp-p

 

Power Requirements

Line Voltage and Frequency -

100 to 240 VAC ±10% 50/60 HZ.

115 V AC ±10% 400 HZ.

 

Environmental characteristics

Temperature -

Operating: +10 °C to +40 °C.

Nonoperating: -22 °C to +60 °C.

 

Relative Humidity -

Operating (Floppy disk and CD-ROM not installed):

20% to 80% at or below 40 °C (upper limit de-rates to 45% relative humidity at 40 °C).

Nonoperating:

5% to 90% at or below 60 °C (upper limit de-rates to 20% relative humidity at +60 °C).

 

Altitude -

Operating: 3,048 m (10,000 ft.).

Nonoperating: 12,190 m (40,000 ft.).

 

Electromagnetic Compatibility - 89/336/EEC.

Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010-1.