| Data-logging software PC Link / PC Link Plus |
| General
Information |
| Enhanced
operation efficiency by means of data retrieval software,
PC Link Plus, which can handle measurements for up to
a maximum of 8 channels. The PC Link system
is the software dedicated to a PC for retrieving data
outputted from a SANWA digital Multi Meter (PC series).
The operation screen displays graphs in real time
to allow you to check changes in measured values (voltage,
current. etc.) with ease. Measured data can be saved
on a CSV file, so it is easily processed on Excel.
The ease of use in a variety of applications from
data retrieval, processing and analysis holds this
system in high esteem, resulting in its extensive
acceptance for business, education and personal use.
Flexible support for diversified
environments
A digital Multi Meter set at a certain measuring point
concurrently monitors and measures various factors
such as voltage, current and frequency on up to eight
channels (with the use of PC Link Plus). RS232C, USB
or LAN cable can be used to allow flexible connection
between a digital Multi Meter and a PC (PC20 alone).
Concurrent measurements can be made even in an environment
with various interfaces mixed. ?PC connecting cable
is available as an option.
Major features :
MAX 8 (eight) CHANNELS !!
* Automatically detects a port connected with a digital
Multi Meter (except the case of LAN connection).
* The retrieval interval can be set from 1 second.
* Allows viewing the previous screen while retrieving
data.
* Allows automatic retrieval by schedule setting.
* Allows data saving in a CSV format with the date
and time appended.
* The Y axis of a graph can be divided into 10.
* Allows automatic e-mail transmission attached with
measurement data (Outlook Express Ver.6 and higher)
* Allows data import to Excel in up to 65,536 lines.
An example of multi-channel
connection
|
| Features |
| The software can work with only
Sanwa digital Multi Meter (DMM) PC series. Display
* Real time graph display with scaled grid
* Scroll graph
* Zoom In, Zoom Out, Scroll Up, Scroll Down graph
* Overlapped display bit map graph and CSV data graph
* Display maximum and minimum value with time and
date
* Past data can be seen by graph during data acquisition
* Cursor position can be indicated by graph cursor
* Move graph to any position by using find function
(search letter function)
Print
* Printing graph
* Bit map graph and CSV data can be seen in a screen
and can be printed.
Acquisition
* Select acquisition time intervals
* Data acquire every day during the time set, or during
period set
Save
* Saved data by CSV format with date and number
* Saved graph as a bit map file. (BMP)
Calculation (ch1 only)
* Alarm when the value goes out of limit
* Relative value from reference
* Change of the decimal point position and unit
* Line alike by 10 polygonal lines
Communication
* Watch remote DMM data via LAN
* Send data by E-mail
* Send data attached mail automatically in every selected
interval
* Send data attached alarm mail when limit become
active
* Send data request command mail to get data from
remote site
Signal Output
*Output limit result to the RS-232C port
Accessory
* Expand measuring function by optional accessories.
(Temperature probe, Clamp current probe)
DMM Interface
* Support RS-232C
* Support USB (Recognize as RS-232C on Windows)
* Support LAN (By LAN adapter for PC20)
Others
* Copy graph to clipboard
* Direct data transfer to MS-Excel
* Import data from PC520M memory.
More functions with PC
Link Plus
* Max 8 channels data acquisition
* Real time 8 channels graph display with scaled grid
* Direct 8 channels data transfer to Excel
* 8 channels cursor position can be indicated by graph
cursor
* Watch 8 channels remote data through LAN
* Edit multiple PC520M single channel files to multi
channel file format.
Considerations
* For multi channel data acquisition, multiple 232C
interface are necessary.
* When measuring temperature by T-300PC, you cannot
read temperature value from DMM, but you can read
temperature by computer.
* When clamp current probe measurement, DMM display
mV or V, but your computer display A (ampere).
* 9999uF ranges of PC500, 510, 520M, 5000 cannot be
used by PC Link Plus. 9999uF ranges of PC500, 510, 520M,
5000 cannot be used by PC Link Plus.
* For E-mail function, constantly connected to the
Internet and E-mail environment is necessary.
* MS, Windows, Excel, Visual Basic ,Visual C++ , Pentium
,are either trademarks or registered trademarks.
* All other company names, products are either trademarks
or registered trademarks of their respective owners. |
| Applicable
models |
| Software |
Version |
Support OS |
Applicable Models |
| DMM Link |
1.00, 2.00, 2.01, 2.02, 2.03
* To update (change) to the PC Link latest version,
please mail us your serial number, and proof of
date & place of purchase. |
Windows95 98 NT4.0 |
PC100, PC101, PC10 |
| PC Link |
1.00, 1.01, 1.02
* For version 1.00 users :
To update (change) software to the latest version,
please mail us your serial number, and proof of
date & place of purchase. |
Windows95 98 NT4.0 2000 |
PC100, PC101, PC10, PC1000 |
| 1.10, 1.11, 1.12, 1.13 |
Windows95 98 98SE ME NT4.0
2000 |
PC100, PC101,
PC10, PC20, PC1000, PC5000, PC520M, PC510, PC500 |
| 2.10 |
Windows 98 98SE ME 2000 XP |
| PC Link Plus |
1.00, 1.01
* For version 1.00 users :
To update (change) software to the latest version,
please mail us your serial number, and proof of
date & place of purchase. |
Windows95 98 NT4.0 2000 |
PC100, PC101, PC10, PC1000 |
1.10, 1.11, 1.12, 1.13
|
Windows95 98 98SE ME NT4.0
2000 |
PC100, PC101,
PC10, PC20, PC1000, PC5000, PC520M, PC510, PC500 |
| 2.10 |
Windows 98 98SE ME 2000 XP |
|
| Connecting
Cable to DMM |
| 1 |
2 |
3 |
KB-RS2 (Front)
|
KB-RS2 (Back)  |
PC5 Series (Back)
 |
| 4 |
5 |
6 |
Pull up tilt stand
 |
Set adapter
 |
Screw to fix  |
|
| Applicable Cables |
Models
|
Ethernet
LAN
(To connect DMM to LAN) |
Applicable
Cables
( To connect DMM to PC) |
| USB |
RS232C |
| PC10 |
Not Available |
KB-USB |
KB-RS1 |
| PC20 |
KB-LAN |
PC5000
PC520M
PC510
PC500 |
Not Available |
KB-USB2 |
KB-RS2 |
* To use USB
cable, software version 1.13 or later is necessary.
* To use KB-LAN (LAN adapter), software version
2.10 or later is necessary. |
|
|