| Specifications |
| CRT |
| Type |
6-inch rectangular type
with internal graticule
8 x 10 div (1div=1cm) |
| Z-Axis Input |
Input Impedance: Approx. 47k£[
Sensitivity: Above 5Vp-p
Bandwidth: DC ~ 2MHZ |
| VERTICAL SYSTEM |
| Sensitivity |
5mV/div~5V/div¡Ó3%,x5MAG¡Ó5% |
| Bandwidth |
DC (AC 10HZ) ~ 20MHZ(-3dB)
DC (AC 10HZ) ~ 7MHZ(-3dB) at x5MAG |
| Rise Time |
17.5ns (50ns at x5MAG) |
Input Impedance
|
Approx. 1M£[ |
Input Coupling
|
AC, DC, GND |
| Vertical Mode |
CH1, CH2, DUAL (ALT/CHOP), ADD,
CH2 INV |
| HORIZONTAL
SYSTEM |
Sweep Time
|
0.2µs ~ 0.5s/div¡Ó3%
100ns ~ 50ms/div¡Ó5% (x 10 MAG)
2 0ns ~ 50ns/div : uncalibrated |
| TRIGGER |
| Trigger Mode |
AUTO, NORM, TV-V, TV-H |
| Trigger Source |
CH1, CH2, ALT, LINE, EXT |
| Trigger Coupling |
AC |
| Trigger Slope |
"+" or "-" |
| X-Y OPERATION |
| Sensitivity |
5mV ~ 5V/div¡Ó4% |
X-axis Bandwidth
|
DC ~ 500KHZ |
| Phase Error |
3¢X or less from DC ~ 50KHZ |
| OUTPUT SIGNAL |
Trigger Signal Output
|
Voltage: approx. 20mV/div into 50£[ |
| Calibrator Output |
1KHZ Square wave, 2Vp-p¡Ó2% |
| POWER SOURCE |
| |
AC 115V/230V¡Ó15%,
50HZ/60HZ |
| ACCESSORIES |
| |
Instruction manual x 1
Power Cord x 1
GCP-210LC Probes (10:1/1:1) x 2 |
| DIMENSIONS
& WEIGHT |
| |
310(W) x 150(H) x 455(D) mm;
Approx. 8kg |
|