Digital Oscilloscope
Probe for oscilloscopes
Signal / Function Generators
Arbitrary Function Generators
Arbitrary Waveform Generators
Spectrum Analyzer
Real Time Spectrum Analyzer
Logic Analyzers
Electric Safety TesterAlt
AC Power MeterAlt
Power Supplies
Digital Frequency CounterAlt
Component Testing Instruments
Other Instruments
Alt

 
DPO4000 Series Digital Phosphor Oscilloscopes: Debug Smarter, Not Harder!

Features:
  • 1 GHZ, 500, 350 MHZ Bandwidth Models
  • 2 and 4 Channel Models
  • Sample Rates Up to 5 GS/s on All Channels
  • 10 Megasample Record Length on All Channels
  • 3,700 wfms/s Maximum Waveform Capture Rate
  • Wave Inspector™ Controls Provide Unprecedented Efficiency in Waveform Analysis
  • I2C, SPI, CAN Serial Triggering and Analysis
  • 10.4 in. (264 mm) XGA Color Display
  • Small Footprint and Lightweight - only 5.4 in. (137 mm) deep and 11 lbs. (5 kg)!
  • USB and CompactFlash on Front Panel for Quick and Easy Storage
  • Built-in Ethernet Port
  • Plug ‘n’ Play Connectivity and Analysis Software Solutions
  • USB 2.0 Device Port for Direct PC Control of Oscilloscope using USBTMC
  • Suite of Advanced Triggers
  • e*Scope® Remote Viewing and Control
  • Interoperability with Tektronix Logic Analyzers
  • TekVPI™ Probe Interface Supports Active, Differential and Current Probes for Automatic Scaling and Units
Digital Oscilloscopes
DPO4000

Applications

  • Embedded Design and Debug
  • Investigation of Transient Phenomena
  • Power Measurements
  • Video Design and Debug
  • Spectral Analysis
  • Automotive Electronics Design and Debug
  • Manufacturing Test and Quality Control
  • Electro-mechanical Design and Analysis
  • Bio-medical Product Development
  • Industrial Control
Vertical System
  DPO4032 DPO4034 DPO4054 DPO4104
Input Channels 2 4 4 4
Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div 350 MHZ 350 MHZ 500 MHZ 1 GHZ
Calculated Rise Time 5 mV/div (typical) 1 ns 1 ns 700 ps 350 ps
Hardware Bandwidth Limits 20 MHZ or 250 MHZ
Input Coupling AC, DC, GND
Input Impedance 1 MΩ ±1%, 50 Ω ±1%
Input Sensitivity, 1 MΩ 1 mV/div to 10 V/div
Input Sensitivity, 50 Ω 1 mV/div to 1 V/div
Vertical Resolution 8 bits
Max Input Voltage, 1 MΩ 250 VRMS with peaks ≤±400 V
Max Input Voltage, 50 Ω 5 VRMS with peaks ≤±20 V
DC Gain Accuracy ±1.5% with offset set to 0 V
Offset Range

   1 mV/div to 50 mV/div

   50.5 mV/div to 99.5 mV/div

   100 mV/div to 500 mV/div

   505 mV/div to 995 mV/div

   1 V/div to 5 V/div

   5.05 V/div to 10 V/div

 50 Ω

±1 V

±0.5 V

±10 V

±5 V

±100 V

±50 V

1 MΩ

±1 V

±0.5 V

±10 V

±5 V

±5 V

NA

Channel-to-channel Isolation (Any Two Channels at Equal Vertical Scale) ≥100:1 at ≤100 MHZ and ≥30:1 at >100 MHZ up to the rated bandwidth

Horizontal System

  DPO4032 DPO4034 DPO4054 DPO4104
Maximum Sample Rate (all channels) 2.5 GS/s 2.5 GS/s 2.5 GS/s 5 GS/s
Maximum Record Length (all channels) 10 M points
Maximum Duration at Highest Sample Rate (all channels) 4 ms 4 ms 4 ms 2 ms
Timebase Range (s/div) 1 ns to 1,000 s 400 ps to 1,000 s
Timebase Delay Time Range -10 divisions to 50 s
Channel-to-channel Deskew Range ±100 ns
Long Term Sample Rate and Delay Time Accuracy ±5 ppm over any ≥1 ms interval
Delta Time Measurement Accuracy ±(1/sample rate + 5 ppm × |Reading| + 0.4 ns)
Trigger System

Main Trigger Modes - Auto, Normal, and Single.

Trigger Coupling - DC, HF reject (attenuates >50 KHZ), LF reject (attenuates <50 KHZ), noise reject (reduces sensitivity).

Trigger Holdoff Range - 20 ns to 8 s.

Sensitivity

Internal DC Coupled - 0.4 div DC to 50 MHZ increasing to 1 div at rated bandwidth.

External (auxiliary input) - 200 mV from DC to 50 MHZ increasing to 500 mV at 250 MHZ.

Trigger Level Range

Any Channel - ±8 divisions from center of screen.

External (auxiliary input) - ±8 V.

Acquisition Modes

Sample - Acquire sampled values.

Peak Detect - Captures narrow glitches at all real-time sampling rates.

Averaging - From 2 to 128 waveforms included in average.

Envelope - Min-max envelope reflecting Peak Detect data over multiple acquisitions.

Hi-Res - Real-time boxcar averaging reduces random noise and increases resolution.

Roll - Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40 ms/div.

 

Trigger Modes

Edge - Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, HF reject, LF reject, and noise reject.

Pulse Width - Trigger on width of positive or negative pulse that are >, <, = or ≠ a specified period of time.

Runt - Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.

Logic - Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as High, Low or Don't Care.

Setup & Hold - Trigger on violations of both setup time and hold time between clock and data present on any two input channels.

Rise/Fall Time - Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either.

Video - Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.

I2C (Optional) - Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address & Data on I2C buses up to 3.4�Mb/s.

SPI (Optional) - Trigger on SS, MOSI, MISO, or MOSI & MISO on SPI buses up to 10.0 Mb/s (4 channel models only).

CAN (Optional) - Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier & Data, End of Frame, or Missing ACK on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >, ≥ or ≠ a specific data value. User adjustable sample point is set to 50% by default.

Trigger Delay by Time - 4 ns to 8 s.

Trigger Delay by Events - 1 to 9,999,999 events.

Waveform Measurements

Cursors - Waveform and Screen.

Automatic Measurements - 25, of which up to 4 can be displayed on screen at any one time. Measurements include Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Area, and Cycle Area.

Measurement Statistics - Mean, Min, Max, Standard Deviation.

Reference Levels - User definable reference levels for automatic measurements can be specified in either percent or units.

Gating - Isolate the specificoccurrence within an acquisition to take measurements, on using either the screen or waveform cursors.

Waveform Math

Arithmetic - Add, subtract, multiply, and divide waveforms.

Math Functions - Integrate, Differentiate, FFT.

FFT - Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.

Advanced Math - Define extensive algebraic expressions including waveforms, math functions, scalars, up to two user adjustable variables, and results of parametric measurements e.g. (Intg(Ch1-Mean(Ch1)) × 1.414 × VAR1).

Software

National Instruments SignalExpressT Tektronix Edition - A fully interactive measurement software environment optimized for the DPO4000 Series, enables you to instantly acquire, generate, analyze, compare, import and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard DPO4000 Series support for acquiring, controlling, viewing, and exporting your live signal data is permanently available through the software. Additional signal processing, advanced analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities are available for a 30 day trial period and can be activated at any time for a minimal license fee by contacting National Instruments.

OpenChoice® Desktop - Enables fast and easy communication between a Windows PC and the DPO4000 Series, via USB or LAN. Transfer and save settings, waveforms, measurements, and screen images.

IVI Driver - Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET, and MATLAB.

Display Characteristics

Display Type - 10.4" (264 mm) liquid crystal TFT color display.

Display Resolution - 1,024 horizontal×768 vertical pixels (XGA).

Waveform Styles - Vectors, Dots, Variable Persistence, Infinite Persistence.

Input/Output Ports

CompactFlash Drive - Front panel access (Type 1).

USB 2.0 Full Speed Host Port - Supports USB mass storage devices and printers. Two ports available on rear-panel and one on front-panel.

USB 2.0 High Speed Device Port - Rear panel connector allows for control of oscilloscope via USBTMC or GPIB with a TEK-USB-488.

LAN Port - RJ-45 connector, supports 10/100Base-T.

XGA Video Port - DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector.

Auxiliary Input - Front panel BNC connector. Input Impedance 1 MΩ. Max input 250 VRMS with peaks ≤±400 V.

Probe Compensator Output - Front panel pins. Amplitude 2.5 V. Frequency 1 KHZ.

Trigger Out - Rear-panel BNC connector, provides a positive polarity pulse when the oscilloscope triggers.

TekLinkT Adapter - Connector provided for future multi-instrument connectivity.

Kensington Lock - Rear-panel security slot connects to standard Kensington lock.

Power Source

Power Source Voltage - 100 - 240 V ±10%

Power Source Frequency - 47 - 66 HZ (90 to 264 V), 360 - 440 HZ (100 to 132 V)

Power Consumption - 250 W maximum

General Characteristics

Physical Characteristics

Dimensions mm in.
Height 229 9.0
Width 439 17.3
Depth 137 5.4
Weight kg lbs.
Net 5 11
Shipping 10 22
   
Rackmount Configuration 5U

Cooling clearance - 2 in. (51 mm) required on left side and rear of instrument

Environmental

Temperature

Operating - 0 °C to +50 °C

Non-Operating - -20 °C to +60 °C

Humidity

Operating -

High: 40 °C to 50 °C, 10% to 60% Relative Humidity.

Low: 0 °C to 40 °C, 10% to 90% Relative Humidity.

Non-Operating -

High: 40 °C to 60 °C, 5% to 60% Relative Humidity.

Low: 0 °C to 40 °C, 5% to 90% Relative Humidity.

Altitude

Operating - 3,000 meters (9,843 feet).

Non-Operating - 12,000 meters (39,370 feet).

Random Vibration

Operating - 0.31 GRMS from 5 to 500 HZ, 10 minutes each axis, 3 axes, 30 minutes total

Non-Operating - 2.46 GRMS from 5 to 500 HZ, 10 minutes each axis, 3 axes, 30 minutes total

Regulatory

Electromagnetic Compatibility - 89/336/EEC

Safety - UL61010-1, Second Edition; CSA61010-1 Second Edition, EN61010-1: 2001; IEC 61010-1: 2001.