370 B : Programmable Curve Tracers

General Information
  • High-resolution DC Parametric Measurements With the 370B (Resolution Down to 1 pA or 2 µV)
  • High Voltage and Current Sourcing With the 371B (Up to 3,000 V or 400 A)
  • Built-in Cursor Measurements - Dot, Window and Function Line
  • Kelvin Sense Measurements
  • Sweep Measurement Mode
  • Waveform Comparison and Averaging
  • Fully Programmable
  • 1.44 MB Floppy Drive Stores Setup and Bitmap of Curves
    Direct Hardcopy with Third-party Printer
LCR Meter
Hand Held Meter
D. C. Milli Ohm Meter
I. C. Tester
Curve Tracer
370 B
Safety Testing Instruments

Applications
  • Parametric Characterization of Semiconductors
  • Failure Analysis
  • Data Sheet Generation
  • Manufacturing Test
  • Process Monitoring and Quality Control
  • Incoming Inspection
  • Component Matching
Characteristics
370B Curve Tracer Characteristics

Collector Supply

Peak Voltage (Range)

16 V

80 V

400 V

2,000 V

Polarity Modes

AC, ± DC, ± Leakage, ± Rectified Sine

Available Current

Peak Current

10 A

2 A

0.4 A

0.05 A

Peak Current   (PULSE mode)

20 A

4 A

0.8 A

0.1 A

Available Resistance

Minimum   Series  Resistance

0.26 O

6.4 O

160 O

20 kO

Maximum  Series  Resistance

800 O

20 kO

500 kO

12.5 MO

Available Peak Power

16, 80 and 400 V Range - 0.08, 0.4, 2, 10, 50, 220 W.

2,000 V Range - 0.08, 0.4, 2, 10, 50 W.

Variable Collector Supply Settings As a % of Maximum Peak Voltage - 0 to 100% in 0.1% increments.

Looping Compensation (typical) Range - at least 100 pF.

Step Generator

Accuracy

Incremental - 1.5%.

Absolute - Less than 1.5% of total output + 3% x STEP AMPLITUDE setting + 1 mV or 1 nA.

Offset Control Range - Variable from -10 to +10 times STEP AMPLITUDE.

Resolution - STEP AMPLITUDE setting x 1%.

Current Mode

Amplitude Range - 50 nA to 200 mA in a 1-2-5 sequence of 21 steps.

Maximum Current - 20x STEP AMPLITUDE setting, 10x STEP AMPLITUDE setting when control is set to 200 mA.

Maximum Voltage - At least 10 V.

Maximum Opposing Offset Current - 10x STEP AMPLITUDE.

Maximum Opposing Volts - Less than 15 V.

Ripple Plus Noise - Less than 0.5% x STEP AMPLITUDE + 10 nA.

Voltage Mode

Amplitude Switch Range - 50 mV to 2 V, in a 1-2-5 sequence of 6 steps.

Maximum Voltage - 20x STEP AMPLITUDE.

Maximum Current - At least 500 mA at 10 V or less, at least 200 mA at 15 V, at least 10 mA at 40 V.

Short Circuit Current Limiting - 500 mA, +50%, -20%.

Maximum Opposing Offset Current - 10x STEP AMPLITUDE.

Maximum Opposing Current - Less than 20 mA.

Ripple Plus Noise - Less than 0.5% x STEP AMPLITUDE + 10 mV.

Step Rates - 2x line frequency (1 x line frequency in AC collector supply mode). Stepsoccur at 0 collector voltage.

Pulsed Steps - 80 µs or 300 µs wide, ±10%.

Steps and Offset Polarity - Corresponds to Collector Supply Polarity when STEP GENERATOR POLARITY INVERT is disabled. Opposite to Collector Supply Polarity when STEP GENERATOR POLARITY INVERT is selected or CONFIGURATION switch is set to BASE COMMON. BASE COMMON configuration disables STEP GENERATOR POLARITY INVERT.

Number of Steps - Ranges from 0 to 10.

AUX Supply

Range - From -40 to +40 volts, with 20 mV step resolution.

Accuracy (typical) - Within 50 mV + 1.5% of total output.

Output Current - At least 100 nA at ±20 V.

At least 10 mA at ±40 V.

Ripple Plus Noise - Less than 50 mVp-p.

Non-store Vertical Deflection System

Collector/Base Current

Range - 1 µA/div to 2 A/div in a 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 100 nA/div (1 nA resolution).

Accuracy (typical) - Within 2% of WINDOW cursor readout + 0.1 x VERT/DIV setting.

Emitter Current

Range - 1 nA/div to 2 mA/div in a 1-2-5 sequence X10 MAG extends maximum sensitivity to 100 pA/div.

Accuracy (typical) - Within 2% of WINDOW cursor readout + 0.1 x VERT/DIV settings + 1 nA.

Maximum Displayed Noise or Ripple - Depending on setting of MAX PEAK VOLTS.

Max. Volts Range

16 V

80 V

400 V

2000 V

Noise or Ripple

1 nAp-p

1 nAp-p

2 nAp-p

5 nAp-p

Step Generator Display

Range - 1 step/division.

1 step/10 divisions with X10 MAG.

10 steps/division with STEP MULTI .1x.

Accuracy - Within 0.3 division.

Display Offset (typical)

Range - ±10 divisions with 0.1 div resolution.

Accuracy - Within 1.5% of offset + 0.1 x VERT/DIV setting.

Display X10 MAG (typical)

Accuracy - Within 1.5% of window cursor readout + 0.3 x VERT/DIV setting.

Display Invert (typical)

Accuracy - Within 0.1 x VERT/DIV setting.

Digital Storage Vertical Acquisition

A/D Converter

Resolution - 10-Bits for 10.24 divisions, 100 counts per division.

Max. Data Points - 1024.

Max. Sampling Rate - Line frequency x 1024.

Min. Sampling Rate - Line frequency x 2.

Collector/Base Current

Range - 1 µA/div to 2 A/div in a 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 100 nA/div (1 nA resolution).

Accuracy - Within 1.5% of DOT cursor readout +0.05 x VERT/DIV setting.

Emitter Current

Range - 1 nA/div to 2 mA/div in a 1-2-5 sequence.

X10 MAG extends max sensitivity to 100 pA/div (1 pA resolution).

Accuracy - Within 1.5% of DOT cursor readout +0.05 x VERT/DIV setting + 1 nA.

Step Generator Display

Range - 1 step/division, 1 step/10 divisions with X10 MAG, 10 steps/division with STEP MULTI .1x.

Accuracy - Within 0.3 division.

Display Offset (typical)

Range - ±10 divisions with 0.1 div resolution.

Accuracy - Within 1.5% of offset + 0.06 x VERT/DIV setting.

Display X10 MAG (typical)

Accuracy - Within 1.5% of window cursor readout + 0.3 x VERT/DIV setting.

Display Invert (typical)

Accuracy - Within 0.04 x VERT/DIV setting.

Non-store Horizontal Deflection System

Collector Volts

Range - 50 nV/div to 500 V/div in a 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 5 mV/div (50 µV resolution).

Accuracy (typical) - Within 2% of WINDOW cursor readout + 0.1 x HORIZ/DIV setting.

Base/Emitter Volts

Range - 50 mV to 5 V/div in a 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 5 mV/div (50 µV resolution).

Accuracy (typical) - Within 2% of WINDOW cursor readout + 0.1 x HORIZ/DIV setting.

Step Generator Display

Range - 1 step/division, 1 step/division with X10 MAG, 10 steps/division with STEP MULTI .1x.

Accuracy - Within 0.3 division.

Display Offset

Range - ±10 divisions in 0.1 division steps.

Accuracy - Within 1.5% of offset +0.1 x HORIZ/DIV setting.

Display X10 MAG

Accuracy - Within 1.5% of window cursor readout + 0.3 x HORIZ/DIV setting.

Display Invert

Accuracy - Within 0.1 x HORIZ/DIV setting.

Digital Storage Horizontal Acquisition

A/D Converter

Resolution - 10 bits for 10.24 divisions, 100 counts per division.

Max. Data Points - 1024.

Max. Sampling Rate - Line frequency x 1024.

Min. Sampling Rate - Line frequency x 2.

Collector Volts

Range - 50 mV/div to 500 V/div in a 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 5 mV/div (50 µV resolution).

Accuracy - Within 1.5% of DOT cursor readout + 0.05 x HORZ/DIV setting.

Acquisition Modes

Normal, Envelope, and Average. Envelope is Vertical or Horizontal. Average is moving average with weight of 1/16.

Safety

Standards Met - UL3111-1, CAN/CSA C22.2 NO. 1010.1, EN 61010-1 with second amendment.

371B Curve Tracer Characteristics

Collector Supply

Modes (positive and negative polarities for both modes) - High current: 250 µs pulses with maximum peak of 30 V.

High voltage: Full rectified sine wave with maximum peak of 3,000 V.

Polarity Modes - NPN +.

PNP -.

   

High Voltage Mode

High Current (pulsed) Mode

High Current (pulsed) Mode

Peak Power Watts (range)

30 mW

300 mW

3 W

30 W

300 W

3 kW

  Collector   Peak  Current

0.4 mA ±20%

4 mA ±20%

4 mA ±20%

40 mA ±20%

40 A

400 A

  Maximum   Peak  Voltage

300 V + 15% - 0%

300 V + 15% - 0%

3 kV + 10% - 0%

3 kV + 10% - 0%

30 V + 10% - 5%

30 V + 10% - 5%

Variable Collector Supply Range - Continuously variable from 0% to 100% in 0.1% increments.

Looping Compensation (high voltage mode) - Stray capacitance between collector terminal and ground is compensated for up to a maximum of 100 pF.

Pulsed Collector Supply Repetition Rate -

3 kW: 1/4 (0.25 x) line frequency.

300 W: 1/2 (0.5 x) line frequency.

Pulse Width (half amplitude) - 250 µs ±10% (more than 30% of collector supply).

Circuit Breakers - Both the high-voltage and the high-current supplies have breakers which operate independently. The high-current output breaker opens automatically in an over-current condition. Both breakers can be operated manually.

Step Generator

Offset Control Range - Variable 0 to 10 times STEP/OFFSET AMPLITUDE setting. However, 0 to 5 times when STEP/OFFSET AMPLITUDE is 5 V or 2 A.

Number of Steps - 0 to 10. However, 0 to 5 when STEP/OFFSET.

Step Polarity - Positive, Negative.

Step Rate -

Pulse:

   3 kW: 1/4 (0.25x) the line frequency, 300 W: 1/2 (.5X) the line frequency.

Stairstep:

   300 W, 3 W, 300 mW, 30 mW: 2x the line frequency.

Current Mode

Amplitude Range

Normal Step - 1 µA to 2 mA in 1-2-5 sequence. COLLECTOR SUPPLY HIGH VOLTAGE MODE (30 W/3 W and 300 mW/30 mW).

Pulsed Step - 1 mA to 2 A in 1-2-5 sequence. COLLECTOR SUPPLY HIGH CURRENT MODE (3 kW/300 W).

Maximum Current - 20 x step amplitude, except 10 times STEP/OFFSET AMPLITUDE when control is set to 2 A per step.

Maximum Voltage - 12 V ±30%.

Accuracy: At least 5 V.

Ripple Plus Noise - Within 1% of STEP AMPLITUDE + 10 nA.

Voltage Mode

Step Amplitude Range - 200 mV to 5 V in 1-2-5 sequence.

Short Circuit Current Limiting - 100 mA +50%, -20%.

Maximum Voltage - 10 x STEP AMPLITUDE, with 5 V setting.

20 x STEP AMPLITUDE, except 5 V setting.

Ripple Plus Noise - Within 1% of STEP AMPLITUDE + 10 mV.

Vertical Deflection System

Collector Current (lc) Range

3 kW Peak Power - 1 A/DIV to 50 A/DIV.

300 W Peak Power - 500 mA/DIV to 5 A/DIV.

30 W Peak Power - 100 µA/DIV to 5 mA/DIV.

3 W Peak Power - 10 µA/DIV to 500 µA/DIV.

0.3 W Peak Power - 10 µA/DIV to 500 µA/DIV.

0.03 W Peak Power - 1 µA/DIV to 50 µA/DIV.

Collector Current (lc) Accuracy - Within 0.1 DIV to the Vertical graticule lines.

Collector Current (lc) Cursor Accuracy - Within 1.5% of readout +0.1 DIV of the CURRENT/DIV setting.

Horizontal Deflection System

Collector Supply Volts (Vce) Range

3 kW, 300 W Peak Power - 100 mV/DIV to 5 V/DIV in a 1-2-5 sequence.

30 W, 3 W Peak Power - 50 V/DIV to 500 V/DIV in a 1-2-5 sequence.

300 mW, 30 mW Peak Power - 5 V/DIV to 50 V/DIV in a 1-2-5 sequence.

Step Generator Volts (Vbe) Range - 100 mV/DIV to 5 V/DIV in a 1-2-5 sequence.

Step Generator Volts (Vbe) Accuracy - Within 0.1 DIV of Horizontal graticules.

Digital Storage Acquisition

A/D Converter

Resolution - 10 bits for 1024 division, 100 points per one division.

Tolerance - Within ±2 counts.

Max. Data Point - 1024.

Max. Sample Rate - 1024 x line frequency.

Min. Sample Rate - 1/8 x line frequency.

Safety

Standards Met - UL3111-1, CAN/CSA C22.2 NO. 1010.1, EN 61010-1 with second amendment.

About Us - Products - Enquiry - News / Downloads - Contact Us